Basic Info.
After-sales Service
1 Year Warranty
Communication Interface
LAN/RS232
Sense Mode
Four Wires Remote Sense
Protection
Ocp, Ovp, Uvp, Otp, OPP
Display
4.3 Inch LCD Screen
External Control
Analog Programming Function
Voltage Accuracy
0.05%+0.05%F.S.
Current Accuracy
0.1%+0.1%F.S.
Specification
2U height, 19 inch width
Product Description
Laboratory Adjustable Programmable High Precision DC Power Supply
N3600 Series Wide Range Programmable DC Power SupplyDC power supplies provide a regulated DC output to power a component, a module, or a device. A reliable DC power supply must output voltage and current which is stable and precise, with minimal noise to any type of load.Product Introduction
N3600 series is developed based on NGI's years of experience in test for battery fluctuation simulation test, battery charger, high voltage diode, electrolytic capacitor, electromechanical control, ATE test system, etc. It is a high-voltage wide-range programmable DC power supply. According to different test environments in the fields of lab test, system integration test, and mass production line, NGI has made a number of optimization designs based on the international advanced technology. N3600 series is a market leader in similar products in terms of reliability, maintainability and safety.
Application Fields1.Battery fluctuation simulation test
2.Battery charger
3.High voltage diode
4.Electrolytic capacitor
5.Electromechanical control and ATE test system
Main Features
*Voltage up to 1000V
*Different models available in high voltage or high current
*Equipped with LCD screen, numeric buttons and knob to support local operation
*Output control via ON/OFF button
*Editable waveform of voltage & current variation in SEQ function
*Remote sense
*Standard 19-inch 2U, available for benchtop or rack installation
*Built-in RS232/LAN communication interface
*Dual knobs for adjusting voltage and current separately
*Convenient HMI (human-machine interaction) interface on LCD screen
*Editable rise/fall slew rate
*Analog programming (APG) interface, current monitoring interface, remote trigger function to realize complex function control and monitoring
*Multiple protections: OCP, OVP, UVP, OTP, OPP, peripheral control communication error alarm, cascade error alarm
*External dissipater to protect the power supply and DUT
*Built-in RS485 interface for parallel communication
*Multiple devices operation in cascade mode
*Intelligent fan control
*Safety terminals
SEQ function
SEQ function provides setting of output voltage, output current, voltage slew rate, current slew rate and dwell time for single step.
Voltage up to 1000V, making high voltage test more secure
N3600 series supports up to 1000V. In the fields of LED, battery, DC/DC converter and other industries, high voltage is the basic need for power supplies. Besides the above mentioned industries, N3600 series can also be applied for special tests with extremely high voltage requirements.
The safety of high-voltage test has always been a concern of engineers. NGI puts emphasis on details like the safety terminals design to ensure the safety of the test.
Wide range for saving purchase cost
N3600 series' maximum power is not the result of Max. voltage multiplied by Max. current. Let's take model N3630-240-060 for example. The Max. power is 3kW while Max. voltage 240V and Max. current 60A. This feature offers N3600 wider application range, compared with traditional power supply.
External dissipater function
When using N3600 to supply power to inductive loads such as motors, press ON/OFF button on N3600's front panel to stop power supply. At this time, the motor may return a voltage greater than the setting value to N3600, which is likely to damage N3600 and the motor. Users can connect a load to N3600 as a dissipater. The setting voltage of the load must be an increment higher than the setting voltage of N3600. When the setting voltage of the load is higher than the setting voltage of N3600, the load will not work. If the voltage returned by the motor is exceeding the setting voltage of the load, the load starts to work to protect N3600 and the motor controller.
Dual knobs for adjusting voltage and current
N3600 provides separate knobs and buttons to users for adjusting voltage and current.
ExhibitionsProduct Line
For more specification data sheets, please contact us.Model | N3608-080-060 | N3612-080-060 | N3612-240-030 | N3618-016-250 | N3618-080-120 |
Voltage | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Current | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Power | 800W | 1200W | 1200W | 1800W | 1800W |
CV Mode |
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Setting Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Setting Accuracy (23±5ºC) | 0.05%+0.05%F.S. |
CC Mode |
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Setting Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Setting Accuracy (23±5ºC) | 0.1%+0.1%F.S. |
Voltage Measurement |
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Readback Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Readback Accuracy (23±5ºC) | 0.05%+0.05%F.S. |
Temperature Coefficient | 50ppm/ºC |
Current Measurement |
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Readback Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Readback Accuracy (23±5ºC) | 0.1%+0.1%F.S. |
Temperature Coefficient | 50ppm/ºC |
Line Regulation |
Voltage | ≤0.01% |
Current | ≤0.05% |
Load Regulation |
Voltage | ≤0.05% |
Current | ≤0.05% |
Dynamic Characteristics |
Voltage Rise Time (no load) | ≤20ms | ≤20ms | ≤60ms | ≤10ms | ≤20ms |
Voltage Rise Time (full load) | ≤500ms | ≤300ms | ≤500ms |
Voltage Fall Time (no load) | ≤700ms | ≤700ms | ≤300ms | ≤50ms | ≤700ms |
Voltage Fall Time (full load) | ≤20ms | ≤20ms | ≤50ms | ≤5ms | ≤20ms |
Transient Recovery Time | The recovery time of load varying from 10% to 90% and output voltage recovering within 0.5% of rated voltage is less than 20ms. | ≤80ms | ≤20ms |
Output Ripple(20Hz-20MHz) |
Voltage Ripple (P-P) | ≤300mVp-p | ≤300mVp-p | ≤400mVp-p | ≤400mVp-p | ≤400mVp-p |
Others |
Efficiency | 90%(Typical) |
Interface | RS232/LAN |
Communication Response Time | ≤5ms |
AC Input | Single phase, please refer to the voltage mark at the rear panel. |
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC |
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa |
Net Weight | Approx. 15.5kg | 16.5kg | 18kg |
Dimension | 2U, 88.0(H)*482.0(W)*550.0(D)mm |
Address:
No. 101, Building B23-B24, Liandong Jinyu Industrial Center, No. 308, Maqiaohe Road, Changsha City, Changsha, Hunan, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
With over 10 years experience, NGI has become a professional manufacturer of intelligent equipment and test & Control instruments, committed to developing, manufacturing and selling multichannel battery simulators, programmable power supplies, programmable electronic loads, supercapacitor testers, test & Control modules, and many more instruments. The products can be widely used in the industries of battery, power supply, fuel cell, supercapacitor, consumer electronics, new energy vehicle, semiconductor, etc.
NGI offers not only test instruments, but also integration and software writing service. NGI has complete after-sales service system, and has obtained ISO9001: 2015 quality management system and CE certificates for our products.
NGI puts much emphasis on R& D and innovation and maintains close cooperation with many universities, scientific research institutions and industry leaders.
With the target of becoming a reliable and responsible electronic solution provider for intelligent manufacturing, NGI members are always striving and on the way forward.