• Programmable Multi Channel DC Source Used for Laboratory Test
  • Programmable Multi Channel DC Source Used for Laboratory Test
  • Programmable Multi Channel DC Source Used for Laboratory Test
  • Programmable Multi Channel DC Source Used for Laboratory Test
  • Programmable Multi Channel DC Source Used for Laboratory Test
  • Programmable Multi Channel DC Source Used for Laboratory Test

Programmable Multi Channel DC Source Used for Laboratory Test

After-sales Service: 1 Year Warranty
Warranty: 1 Year
Communication Interface: LAN/RS232
Voltage Resolution: up to 1mv
Current Resolution: up to 1mA
Protection: Over Voltage, Over Current, Over Temperature
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Hunan, China
to see all verified strength labels (24)

Basic Info.

Model NO.
N39400
Voltage Accuracy
0.05%+0.1%F.S.
Current Accuracy
0.1%+0.1%F.S.
Output
Four-Output
Size
19 Inch 2u
Sense
Remote/Local Sense
Special Function
Cc CV Priority
Transport Package
Carton
Specification
2U, half 19 inch
Trademark
NGI
Origin
China
HS Code
8504401990
Production Capacity
50000/Year

Product Description

Programmable Multi Channel DC Source Used for Laboratory Test 
N39400 Series High-accuracy Multi-channel Programmable DC Power Supply

Product Introduction
N39400 series is a high-accuracy & multi-channel programmable DC power supply with standard 19-inch 2U design, available for rack installation. N39400 standalone supports Max. 4 channels output, with channels isolated. Both local operation on front panel and remote control on a computer are supported. N39400 can be widely used in lab test, system integration test, production aging line, etc.

Application Fields
1.School laboratory
2.R&D laboratory
3.Production line inspection
4.Maintenance test

Main Features
*Automatic switch between CV and CC mode
*Single device with up to 4 channels, each channel isolated
*Low ripple and low noise
*Remote sense for accurate measurement
*Multiple protections: OVP, OCP, OTP and short circuit
*Intelligent fan control
*Lock function to avoid misoperation
*Dual LAN ports design
*CC&CV priority function
*Equipped with LCD screen and user-friendly interface
*Standard 19-inch 2U, available for rack installation
*LAN port and RS232 interface

Ultra-high integration, single device with up to 4 channels
N39400 series adopts the standard 19-inch 2U design, with Max.4 channels in a single device. Each channel is isolated. One device can support 4-station test simultaneously, which greatly reduces the test equipment quantity and improves test efficiency.

Remote control
N39400 series supports remote control, providing RS232 and LAN port to communicate with the computer, and realizing all functions on the panel via computer application software. Driver packages that support common development
environments such as Visual C ++, Visual Basic, Delphi, C # and Labview are provided.

Remote sense
NN39400 series provides remote sense function, which can transfer the actual voltage of the load back to N39400 so that N39400 can compensate for the output voltage and eliminate lead wire errors.

UI flat icons
UI flat icons offer convenient and quick operation.
Programmable Multi Channel DC Source Used for Laboratory Test
CC&CV priority function
N39400 has the function of selecting priority of voltage-control loop or current-control loop, which enables N39400 to adopt the optimal test mode for different DUTs, and thus protect the DUT.

As shown in figure one, when the DUT requires reducing voltage overshoot during test, such as supplying power to a low-voltage processor or FPGA core, voltage priority mode should be selected to obtain fast and smooth rise voltage.
As shown in figure two, when the DUT requires reducing current overshoot during test, or when the DUT is with low impedance, such as battery charging scenario, current priority mode should be selected to obtain fast and smooth rise current.
Programmable Multi Channel DC Source Used for Laboratory Test
Dual LAN ports for multiple devices control
N39400 is equipped with two LAN ports, which can support multiple devices control for quick adjustment and test.
Programmable Multi Channel DC Source Used for Laboratory Test
Exhibitions

Programmable Multi Channel DC Source Used for Laboratory TestProgrammable Multi Channel DC Source Used for Laboratory TestProgrammable Multi Channel DC Source Used for Laboratory TestProgrammable Multi Channel DC Source Used for Laboratory Test
Product Line
Programmable Multi Channel DC Source Used for Laboratory Test
 
 
Model N39420-60-10 N39436-60-15 N39460-60-15
Voltage 60V/CH
Current 10A/CH 15A/CH 15A/CH
Power 200W/CH 360W/CH 600W/CH
Channels 4CH
CV Mode
Range 0-60V
Setting Resolution 1mV
Setting Accuracy (23±5ºC) 0.05%+0.1%F.S.
Setting Temperature Coefficient 50ppm/ºC
Readback Resolution 1mV
Readback Accuracy(23±5ºC) 0.05%+0.1%F.S.
Readback Temperature Coefficient 50ppm/ºC
CC Mode
Range 0-10A 0-15A 0-15A
Setting Resolution 1mA
Setting Accuracy (23±5ºC) 0.1%+0.1%F.S.
Setting Temperature Coefficient 50ppm/ºC
Readback Resolution 1mA
Readback Accuracy (23±5ºC) 0.1%+0.1%F.S.
Readback Temperature Coefficient 50ppm/ºC

Voltage Ripple(20Hz-20MHz)
200mVp-p
10mVrms
Rise Time ≤30ms
Fall Time ≤50ms
Load Regulation ≤0.01%(Voltage) / ≤0.03%(Current)
Line Regulation ≤0.01%(Voltage) / ≤0.02%(Current)
Others
Interface LAN/RS232
AC Input Single phase, 220V AC±10%, frequency 47Hz~63Hz
Temperature Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating Environment Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric
pressure: 80~110kPa
Net Weight Approx. 10kg
Dimension 2U, 88.0(H)*482.0(W)*560.0(H)mm
 
Model N39420-150-04 N39436-150-06 N39460-150-06
Voltage 150V/CH
Current 4A/CH 6A/CH 6A/CH
Power 200W/CH 360W/CH 600W/CH
Channels 4CH
CV Mode
Range 0-150V
Setting Resolution 5mV
Setting Accuracy (23±5ºC) 0.05%+0.1%F.S.
Setting Temperature Coefficient 50ppm/ºC
Readback Resolution 5mV
Readback Accuracy(23±5ºC) 0.05%+0.1%F.S.
Readback Temperature Coefficient 50ppm/ºC
CC Mode
Range 0-4A 0-6A 0-6A
Setting Resolution 0.1mA
Setting Accuracy (23±5ºC) 0.1%+0.1%F.S.
Setting Temperature Coefficient 50ppm/ºC
Readback Resolution 0.1mA
Readback Accuracy (23±5ºC) 0.1%+0.1%F.S.
Readback Temperature Coefficient 50ppm/ºC

Voltage Ripple(20Hz-20MHz)
200mVp-p
10mVrms
Rise Time ≤30ms
Fall Time ≤50ms
Load Regulation ≤0.01%(Voltage) / ≤0.03%(Current)
Line Regulation ≤0.01%(Voltage) / ≤0.02%(Current)
Others
Interface LAN/RS232
AC Input Single phase, 220V AC±10%, frequency 47Hz~63Hz
Temperature Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC
Operating Environment Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric
pressure: 80~110kPa
Net Weight Approx. 10kg
Dimension 2U, 88.0(H)*482.0(W)*560.0(H)mm
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
18600000 RMB
Plant Area
>2000 square meters