Basic Info.
After-sales Service
1 Year Warranty
Communication Interface
LAN/RS232
Voltage Resolution
up to 0.1mv
Current Resolution
up to 0.1mA
Protection
Over Voltage, Over Current
Voltage Accuracy
0.01%+10mv
Current Accuracy
0.05%+5mA
Specification
2U, half 19 inch
Product Description
32 Volt DC 3.0 Amp Three Output Benchtop Programmable Linear Power SupplyN3410 Series Triple-channel Programmable DC Power Supply
Product Introduction
N3410 series is a triple-channel programmable DC power supply with high performance and high reliability. N3410 is with half 19 inch 2U size, integrating three independent output channels, and supporting both front and rear wiring. It has compact size and elegant appearance. N3410 supports both benchtop application with carrying handle and tilt stand, and supports rack installation for system integration. Test and measurement information is displayed intuitively on the 4.3 inch LCD screen. The optional DVM measurement function can be used for multi-scene test needs.
Application Fields
School laboratory
R&D laboratory
Production line inspection
Maintenance test
Main Features
Each channel isolated, programmable and controllable High accuracy and resolution, as low as 0.1mV/0.1mA *1*Low ripple&noise, Vrms less than 400μV, Vp-p less than 5mVDynamic response time less than 50μsSequence(SEQ) test function *2*Half 19 inch 2U size with tilt standProgrammable hardware OVP and OCP protectionHigh accuracy DVM measurement (for N3411P/N3412P/N3413P only)Supporting series, parallel and trace output modes Front and rear output terminalsIntelligent fan controlGraph for real-time output waveform display *3*Remark 1: N3411E/N3412E/N3413E are with 10mV/1mA resolution.
Remark 2: SEQ is not available for N3411E/N3412E/N3413E.
Remark 3: Graph is not available for N3411E/N3412E/N3413E.Front and rear wiring design
N3410 series supports both front and rear panel wiring. User can place N3410 on the bench top or integrate it on the rack, which brings a convenient experience.High accuracy and low ripple
N3410 has excellent performance in output accuracy. It also has ultra-low ripple &noise. The ripple Vrms is less than 400μV, and Vp-p less than 5mV.SEQ test function
N3410 series supports sequence edit. Users can set the output voltage, output current and single step running time. 100 groups of voltage and current sequences can be user-defined. Sequence files can also be imported through the USB type-A interface on front panel.
Series, parallel and trace output modes
N3410 series has three output modes: CH1/CH2 series, parallel and trace, which can be switched on the front panel, without external serial and parallel wiring, to meet the needs of different ranges and voltage output.
DVM measurement (for N3411P/N3412P/N3413P only)
N3411P/N3412P/N3413P have built-in one channel high-accuracy DVM to test external voltage, with range of -600V~+600V. It has three automatic ranges: ±600V/±60V/±6V, with measurement accuracy of 0.01% F.S., and measurement resolution of 5½ digit. The measurement data is refreshed on the HD screen in real time, which is convenient to observe the voltage variation.
Graph
Graph can be used to display the output waveform in real time. The waveform display content can be edited, such as voltage-time, current-time, power-time, etc.
Exhibitions
Product Line
For more specification data sheets, please contact us.Model | N3411/N3411P | N3412/N3412P |
Channel | CH1/CH2 | CH3 | CH1/CH2 | CH3 |
Voltage | 32V | 6V | 32V | 6V |
Current | 3A | 3A | 5A | 3A |
Series Mode-Voltage | 64V | N/A | 64V(5A) | N/A |
Parallel Mode-Current | 6A | N/A | 10A | N/A |
Total Power | 210W | 338W |
Setting Resolution-Voltage | 0.1mV | 1mV | 0.1mV | 1mV |
Setting Resolution-Current | 0.1mA | 1mA | 0.1mA | 1mA |
Setting Accuracy-Voltage (23±5ºC) | <0.01%+10mV | <0.03%+10mV | <0.01%+10mV | <0.03%+10mV |
Setting Accuracy-Current (23±5ºC) | <0.05%+5mA | <0.05%+10mA | <0.05%+10mA | <0.05%+10mA |
Setting Temperature Coefficient | 30ppm/ºC |
Readback Resolution-Voltage | 0.1mV | 1mV | 0.1mV | 1mV |
Readback Resolution-Current | 0.1mA | 1mA | 0.1mA | 1mA |
Readback Accuracy-Voltage (23±5ºC) | <0.01%+10mV | <0.03%+10mV | <0.01%+10mV | <0.03%+10mV |
Readback Accuracy-Current (23±5ºC) | <0.05%+5mA | <0.05%+10mA | <0.05%+10mA | <0.05%+10mA |
Readback Temperature Coefficient | 30ppm/ºC |
Long-term Stability | ≤50ppm/1000h |
Voltage Ripple Noise (20Hz~20MHz) | ≤5mVp-p | ≤10mVp-p | ≤5mVp-p | ≤10mVp-p |
Voltage Ripple Noise (20Hz~20MHz) | ≤1mVrms |
Current Ripple Noise (20Hz~20MHz) | ≤3mArms |
Dynamic Characteristics |
Voltage Rise Time (no load) (10%-90%F.S. Variation Time) | 20ms | 20ms | 20ms | 20ms |
Voltage Rise Time (full load) (10%-90%F.S. Variation Time) | 50ms | 21ms | 50ms | 21ms |
Voltage Fall Time (no load) (90%-10%F.S. Variation Time) | 400ms | 200ms | 400ms | 200ms |
Voltage Fall Time (full load) (90%-10%F.S. Variation Time) | 45ms | 13ms | 45ms | 13ms |
Transient Recovery Time | ≤1ms |
Line Regulation-Voltage | ≤0.01%+1mV | ≤0.01%+3mV | ≤0.01%+1mV | ≤0.01%+3mV |
Line Regulation-Current | ≤0.01%+1mA | ≤0.02%+3mA | ≤0.01%+3mA | ≤0.02%+3mA |
Load Regulation-Voltage | ≤0.01%+3mV |
Load Regulation-Current | ≤0.01%+3mA | ≤0.02%+3mA | ≤0.01%+3mA | ≤0.02%+3mA |
DVM Measurement (For N3411P/N3412P Only) |
Channels | 1CH |
Voltage Range | ±600V/±60V/±6V |
Measurement Resolution | 5½ digit |
Measurement Accuracy | 0.01%+0.01%F.S. |
Measurement Frequency | 4Hz |
Input Impedance | 10MΩ |
Terminal | Pluggable terminal |
Temperature Coefficient (0~40ºC) | 20ppm/ºC |
Others |
Isolation (Output to Ground) | 500V DC |
Communication Response Time | ≤5ms |
Interface | LAN/RS232 |
AC Input | Single phase, 220V AC±10%, frequency 47Hz-63Hz |
Temperature | Operating temperature: 0ºC-40ºC, storage temperature: -20ºC~60ºC |
Operating Environment | Altitude <2000m, relative humidity: 5%-90%RH(non-condensing), atmospheric pressure: 80-110kPa |
Net Weight | Approx. 9kg | Approx. 11kg |
Dimension | 2U, 88.0(H)*214.0(W)*398.0(D)mm | 2U, 88.0(H)*214.0(W)*441.0(D)mm |
Model | N3413/N3413P |
Channel | CH1/CH2 | CH3 |
Voltage | 60V | 6V |
Current | 3A | 3A |
Series Mode-Voltage | 120V(3A) | N/A |
Parallel Mode-Current | 6A(60V) | N/A |
Total Power | 378W |
Setting Resolution-Voltage | 0.1mV | 1mV |
Setting Resolution-Current | 0.1mA | 1mA |
Setting Accuracy-Voltage (23±5ºC) | <0.02%+20mV | <0.03%+10mV |
Setting Accuracy-Current (23±5ºC) | <0.05%+5mA | <0.05%+10mA |
Setting Temperature Coefficient | 30ppm/ºC |
Readback Resolution-Voltage | 0.1mV | 1mV |
Readback Resolution-Current | 0.1mA | 1mA |
Readback Accuracy-Voltage (23±5ºC) | <0.02%+20mV | <0.03%+10mV |
Readback Accuracy-Current (23±5ºC) | <0.05%+5mA | <0.05%+10mA |
Readback Temperature Coefficient | 30ppm/ºC |
Long-term Stability | ≤50ppm/1000h |
Voltage Ripple Noise (20Hz~20MHz) | ≤10mVp-p | ≤10mVp-p |
Voltage Ripple Noise (20Hz~20MHz) | ≤1mVrms |
Current Ripple Noise (20Hz~20MHz) | ≤3mArms |
Dynamic Characteristics |
Voltage Rise Time (no load) (10%-90%F.S. Variation Time) | 20ms | 20ms |
Voltage Rise Time (full load) (10%-90%F.S. Variation Time) | 50ms | 21ms |
Voltage Fall Time (no load) (90%-10%F.S. Variation Time) | 800ms | 200ms |
Voltage Fall Time (full load) (90%-10%F.S. Variation Time) | 45ms | 13ms |
Transient Recovery Time | ≤1ms |
Line Regulation-Voltage | ≤0.01%+1mV | ≤0.01%+3mV |
Line Regulation-Current | ≤0.01%+3mA | ≤0.02%+3mA |
Load Regulation-Voltage | ≤0.01%+3mV |
Load Regulation-Current | ≤0.01%+6mA | ≤0.02%+3mA |
DVM Measurement (For N3413P Only) |
Channels | 1CH |
Voltage Range | ±600V/±60V/±6V |
Measurement Resolution | 5½ digit |
Measurement Accuracy | 0.01%+0.01%F.S. |
Measurement Frequency | 4Hz |
Input Impedance | 10MΩ |
Terminal | Pluggable terminal |
Temperature Coefficient (0~40ºC) | 20ppm/ºC |
Others |
Isolation (Output to Ground) | 500V DC |
Communication Response Time | ≤5ms |
Interface | LAN/RS232 |
AC Input | Single phase, 220V AC±10%, frequency 47Hz-63Hz |
Temperature | Operating temperature: 0ºC-40ºC, storage temperature: -20ºC~60ºC |
Operating Environment | Altitude <2000m, relative humidity: 5%-90%RH(non-condensing), atmospheric pressure: 80-110kPa |
Net Weight | Approx. 9kg | Approx. 11kg |
Dimension | 2U, 88.0(H)*214.0(W)*441.0(D)mm |
Address:
No. 101, Building B23-B24, Liandong Jinyu Industrial Center, No. 308, Maqiaohe Road, Changsha City, Changsha, Hunan, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics, Instruments & Meters
Management System Certification:
ISO 9001
Company Introduction:
With over 10 years experience, NGI has become a professional manufacturer of intelligent equipment and test & Control instruments, committed to developing, manufacturing and selling multichannel battery simulators, programmable power supplies, programmable electronic loads, supercapacitor testers, test & Control modules, and many more instruments. The products can be widely used in the industries of battery, power supply, fuel cell, supercapacitor, consumer electronics, new energy vehicle, semiconductor, etc.
NGI offers not only test instruments, but also integration and software writing service. NGI has complete after-sales service system, and has obtained ISO9001: 2015 quality management system and CE certificates for our products.
NGI puts much emphasis on R& D and innovation and maintains close cooperation with many universities, scientific research institutions and industry leaders.
With the target of becoming a reliable and responsible electronic solution provider for intelligent manufacturing, NGI members are always striving and on the way forward.